Centurion gate motor fault finding
Your gate/garagedoor motor is particularly vulnerable due to the nature of it being a motor, switching on and off when used.Ī power surge occurs when the electricity flow is interrupted and then started again, at a higher voltage.
Unfortunately your driveway and garage door gate motor is not spared. Power surge damage can cause havoc with your electrical appliances in your home, particularly fridges, TVs and computers.
Centurion gate motor fault finding professional#
If you’re having trouble shooting your electric fence, contact Gate Repair Services and we will gladly assist you in the efficient and professional manner we’ve become so well known for. When a live wire makes contact with an earth wire, voltage is lost and this triggers the alarm. If all the wires are live – a criminal would easily be able to bypass the fence since there would be no voltage loss to cause the fence alarm to trigger. While doing the inspection particular attention must be put on connectors, insulators and posts.Īdditionally if the electric fence has not been earthed properly this may be causing the fence to be inefficient. The second culprit may be rusted wires which will cause insulation and reduce voltage. In such a case the power supply must be turned off and the branches and shrubbery must be trimmed away. In this case this may be casing a low voltage and may be hindering the proper operation of the fence. Voltage loss is only amplified during rain. One of the primary things to look out for is branches and shrubbery which have overgrown and are touching the fence. This is perhaps the most time consuming step in the electric fence fault finding process as it involves a lot of leg work but the technician can check the voltage to get an idea of where the problem lies before doing a visual inspection. There must be sufficient voltage to power the energizer and the voltage can vary depending on the energizer. The energizer will be unplugged and/or the battery will be disconnected before the power supply is tested. If the energizer is in working condition the next step in the electric fence fault finding process is to check the power supply. If there is insufficient voltage the problem may be the energizer or the circuit board. This is usually done by using a voltmeter which will indicate if there is sufficient voltage. Most electric fence technicians start off by checking the energizer. Gate Repair Services identified that the reason that this fence was shorting was that there was a cable running through one of the insulators. Prior to calling us, the home owners had requested the services of other companies, however, all had failed to identify the problem. Gate Repair Services technicians were called out to assist in finding a fault on an electric fence which, due to repeated shorting, had to be switched off.